PS12015 - - DC-REGULATED POWER SUPPLY
1. Introduction
Thank you for buying the PS12015. Read this manual carefully before bringing the device into service. Make sure
that the device was not damaged in transit. If the device is damaged, don't use it and contact your dealer.
2. Technical Specifications
Input Voltage : AC 230V ±10% ; 50Hz ±2Hz
Output Voltage : 1.2-12V continuously adjustable
Output Current : 1.5A
Ripple & Noise : CV 2.0mVrms
Supply Regulation : CV 1x10
-4
+0.5mV
Load Regulation : CV 5x10
-4
+2mV
Accuracy Voltage : ±1% ± 2 digits
Protection : current-limiting
Operating Temperature : 0 - 40°C
Operating Humidity : <RH80%
Operating Atmospheric Pressure : 86kPa ~ 104kPa
Dimensions (L x W x H) : 115 x 80 x 190mm
Weight : 1.8kg
Fuse : 220V, 0.5A (order code FF0.5N)
3. Front Panel & Operation
1. Voltage indication
2. Black = negative (-) output terminal
3. Red = positive (+) output terminal
4. ON/OFF LED
5. ON/OFF switch
6. Voltage adjustment knob
Connect the device to the mains, switch it on
(#5, LED #4 lights up), adjust the voltage (#6) to
the desired level and connect the desired load.
Mind the polarity.
If the device shouldn't power on, check (and
replace) the fuse at the back. If the device still won't power on, have it repaired by a qualified technician.
4. Notes
- For more accurate voltage reading, connect an external high accuracy meter.
- This unit is short circuit protected. If a short circuit should occur, turn the power supply off and solve the problem.
- Install or store the device in a clean and well-ventilated environment.
- Do not try to open the housing yourself. All repairs should be executed by a qualified technician.
- Disconnect the unit from the mains before maintenance and when it will not be used for a long time.
- The unit can get very hot when you are using a high power output.
- If the unit is defective, the output may exceed the maximum rated voltage. Always keep an eye on the load to
prevent damage.
- This device should be earthed properly.
The information in this manual is subject to change without prior notice.
Vista de pagina 0
1 2 3 4 5

Indice de contenidos

Pagina 1 - 4. Notes

PS12015 1 VELLEMAN PS12015 - - DC-REGULATED POWER SUPPLY 1. Introduction Thank you for buying the PS12015. Read this manual carefully before bring

Pagina 2 - 4. Opmerkingen

PS12015 2 VELLEMAN PS12015 - - REGELBARE DC LABORATORIUMVOEDING 1. Inleiding Dank u voor uw aankoop! Lees deze handleiding aandachtig voor u uw PS

Pagina 3 - 3. Panneau frontal

PS12015 3 VELLEMAN PS12015 - - ALIMENTATION CC REGLABLE 1. Introduction Nous vous remercions de votre achat ! Lisez le manuel attentivement avant

Pagina 4 - 4. Observaciones

PS12015 4 VELLEMAN PS12015 - - FUENTE DE ALIMENTACIÓN CC REGULABLE 1. Introducción ¡Gracias por haber comprado la PS12015! Lea cuidadosamente las

Pagina 5 - 4. Hinweise

PS12015 5 VELLEMAN PS12015 - - DC-LABORNETZGERÄT 1. Einführung Danke für den Kauf des PS12015. Bitte lesen Sie vor Inbetriebnahme diese Bedienung

Comentarios a estos manuales

Sin comentarios