CAD II Overvoltage category II, pollution degree 2 per IEC1010-1
CAT III Overvoltage category III, pollution degree 2 per IEC1010-1
2.2 Maintenance
Do not remove the back cover while a voltage is being applied. Only a qualified technician should handle repairs.
Always disconnect the test leads from all current sources before opening the meter.
Replace the battery when the
symbol is displayed.
Replace blown fuses with an identical one or a fuse with identical voltage and current ratings : F 200mA/250V
(quick-acting, max. resistance 2), F 10A/250V (“quick-acting”).
Use a damp cloth and a mild detergent to clean the device. Never apply abrasives or solvents to the meter
Place the power switch in the OFF position when the device is not being used
Remove the batteries to keep them from leaking if the device is to be stored for a prolonged period of time.
3. Front Panel Description
1. LCD display
2. L/C button : press this button prior to each individual
capacitance and inductance measurement in order to
calibrate the device.
3. Power button (
)
4. Range selector : used to select the desired function and
range
5. Front panel
6. Battery cover
7. 10A jack
8. Capacitor and
, °C, A, V, Hz and H-jack
9. COM jack
10. DC/AC button (DC/AC) : used for AC/DC voltage and
AC/DC current measurements. Place the button in the
pressed-down position for AC current or voltage
measurements or put it in the depressed position for DC
current and voltage measurements.
11. Backlight button (LIGHT)
12. Data-hold button (HOLD)
Low battery
Fuse
AC (alternating current)
DC (direct current)
buzzer for continuity
AC or DC (alternating current or direct current)