9.2. DC Voltage
Ran
e Resolution Accurac
660m
100
0.5% of rd
+ 5 di
its
6.6V 1mV
±(0.8% of rdg + 5 digits) 66V 10mV
660
100m
1000V 1V
1.0% of rd
+2 di
its
Input Impedance: >10MΩ for all ranges
9.3. AC Voltage
Ran
e Resolution Accurac
660m
100
±(1.0% of rdg + 5 digits)
60Hz
6.6V 1mV
40~400Hz
66V 10mV
660
100m
1000V 1V
1.5% of rd
+2 di
its
Input Impedance: >10MΩ for all ranges
Frequency Range: 40 to 400Hz
Overload protection: 1000Vdc or ac rms.
9.4. DC Current
Ran
e Resolution Accurac
660
0.1
A
±(1.0% of rdg + 3 digits)
6.6mA 1
A
66mA 10
A
±(1.5% of rdg + 3 digits)
600m
0.1mA
10A 10mA
1.8% of rd
+5 di
its
When measuring currents > 7A, max. 15s continuous measurement followed by a 15
minutes break between 2 measurements.
Overload Protection: 600mA range F0.63A/1000V– 10A range fuse F10A/1000V
9.5. AC Current
Ran
e Resolution Accurac
660
0.1
A
±(1.5% of rdg + 5 digits)
6.6mA 1
A
66mA 10
A
±(1.8% of rdg + 8 digits)
600m
0.1mA
10A 10mA
2.0% of rd
+ 8 di
its
When measuring currents > 7A, max. 15s continuous measurement followed by a 15
minutes break between 2 measurements.
Overload Protection: 600mA range F0.63A/1000V– 10A range fuse F10A/1000V
9.6. Resistance
Ran
e Resolution Accurac
660.0Ω 0.1
±(1.2% of rdg + 2 digits)
6.600
Ω 1
66.00
Ω 10
660.0
Ω 100
6.600MΩ 1k
66.00MΩ 10
2.0% of rd
+ 5 di
its
Note: in range 660.0, short circuit test leads to determine lead resistance, than
subtract this value from the measured value.