Velleman DVM1200 Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
D
V
c.
6.
Ac
at
E
n
Te
M
a
Fu
S
a
Di
s
O
v
Lo
w
P
o
D
a
B
a
Au
P
o
Di
m
W
e
Ac
V
o
R
a
60
6
V
60
V
60
10
V
M1200
Batter
y
Re
p
Set the rota
Disconnect
Open the b
a
Remove th
e
Install a rep
Close the b
a
Technica
l
c
curac
y
is sp
e
0% ~ 75%.
A
n
vironmental
Pollution D
e
Altitude
Operatin
g
T
Stora
g
e Te
m
mperature
C
a
x. Volta
g
e
b
se Protectio
n
a
mple Rate
s
pla
y
v
er Ran
g
e In
d
w
Batter
y
In
d
o
larit
y
Indicat
a
ta Hold
a
ckli
g
ht
u
to Power-Of
f
o
wer Suppl
y
m
ensions
e
i
g
ht
c
cessories
o
lta
g
e
a
n
g
e
0mV
V
V
0V
00V
To
re
p
dis
p
lacement
r
y
switch to
t
all test lead
s
a
tter
y
comp
a
e
batter
y
.
lacement ba
a
tter
y
comp
a
l
Specific
a
e
cified for o
n
A
ccurac
y
sp
e
Conditions
eg
ree
T
emperature
m
perature
C
oefficient
b
etween Ter
m
n
d
ication
d
ication
ion
f
avoid false
p
lace the ba
t
connect all
t
he OFF pos
i
s
and/or an
y
a
rtment usin
g
tter
y
(
6F22
)
.
a
rtment.
a
tions
n
e
y
ear after
e
cifications t
a
m
inals and E
a
readin
g
s,
w
t
ter
y
as soo
test leads a
i
tion.
connectors
f
g
an appropri
calibration a
t
a
ke the form
1000
V
2
< 200
0
0°C~
4
-10°C
~
0.1x /
C
a
rth 700V
A
µ
A
an
d
A
, F1
0
3x/se
c
3
5/6
di
g
yes (“
O
yes (
“-“ dis
p
yes
white
L
yes
9V ba
t
180 x
8
± 310
g
1 x K-t
softwa
Resolution
0.1mV
1mV
10mV
100mV
1V
w
hich could
l
n as the ba
t
nd/or ant c
o
- 10 -
f
rom the ter
m
ate screwdri
v
t
operatin
g
t
e
of ±
(
% of r
d
V
CAT. II and
0
m
4
0°C or 32°F
~
60°C or 14
°
C
°
(
< 18°C
o
A
C RMS or 1
0
d
mA, F750
m
0
A / 600V, 6.
3
c
for di
g
ital d
a
g
its LCD wit
h
OL
”)
)
p
la
y
ed auto
m
L
EDs
t
ter
y
8
5 x 40mm
g
(
with batte
r
y
pe thermoc
o
re, 1 x 9V b
a
DC Voltage
l
ead to pos
s
t
ter
y
indicat
o
o
nnectors f
r
m
inals.
v
er.
e
mperatures
dg
+ number
600V CAT.
~122°F
(
< 8
0
°
F~140°F
(
<
o
r > 28°C
)
0
00VDC
m
A / 250V, 5
3
x 32mm
a
ta
h
automatic i
n
m
aticall
y
ry)
o
uple, 2 x te
s
a
tter
y
, manu
a
s
ible electri
c
o
r appe
a
r
om an
y
cir
c
of 18°C ~ 2
8
of least si
g
n
i
III
0
% RH, < 1
0
70% RH, b
a
x 20mm
n
dication of
f
s
t leads, 1 x
o
a
l
Accuracy
± (0.5%
o
±
(
0.8%
o
± (1.0%
o
c
shocks or
a
rs. Before
b
c
uit under t
e
8
°C with a r
e
i
ficant di
g
its
)
0
°C
)
a
tter
y
remov
e
f
unctions an
d
o
ptical USB
c
o
f rd
g
± 5 di
g
o
f rd
g
± 5 di
g
o
f rd
g
± 10 di
personal in
j
b
atter
y
repl
a
e
st.
VELLE
M
e
lative humid
.
e
d
)
d
s
y
mbols
c
able, PC-lin
k
its)
its
)
g
its)
j
ur
y
,
a
cement,
M
AN
it
y
k
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 73 74

Comentarios a estos manuales

Sin comentarios