4. Features
high accuracy and rapid response
data hold function
manual scale selection
max. and min. values
low battery indication
5. Overview
Refer to the illustrations on page 2 of this manual.
1 measuring probe 6 range button
2 zero adjust 7 HOLD button
3 LCD 8 MIN/MAX button
4 ON/OFF button 9 backlight ON/OFF button
5 W/B unit select button 10 battery compartment
6. Operation
Refer to the illustrations on page 2 of this manual.
Make sure batteries are present inside the solar power meter. Refer to §8.
Press the power button [4] to switch the power meter on. Press again to
switch off.
Check the measured value with the protective cap on the sensor [1]. The
display must read 00.0. If not, gently rotate the zero adjust [2] until it
does.
Remove the protective cap from the sensor [1]. Place the sensor
horizontally to measure the solar power.
Select the desired measuring unit (W/m² or BTU/ft²xh) with the unit
select button [5].
Note: BTU = British Thermal Unit
When the display indicates ‘OL’, select the appropriate measuring range
with the range button [6].
To freeze the measured value on the display, press the HOLD button [7].
The display indicates HOLD. Press again to exit hold mode.
To show only the highest measured value, press the MIN/MAX button [8].
The display indicates MAX. To see only the lowest measured value, press
the button again. The display shows MIN. Press and hold the MIN/MAX
button [8] for about 3 seconds to return to normal mode.
Press the backlight button [9] to switch the backlight on or off.
After measuring, place the protective cap back on the sensor.
7. Maintenance
Gently wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents. Do not apply pressure on the display.
Never submerge the solar power meter in any liquid.