VMB1TS manual – edition 2 17
Time statistics
For every mode (comfort, day, night or anti-freeze) the time during which the heating or air-conditioning was one is
stored.
These statistics can be recalled or reset via the temperature controller (VMB1TC) or through the Velbus link software
via a PC connected to the Velbus PC interface (VMB1USB, VMB1RS of VMBRSUSB).
Minimum and maximum temperature
The sensor records the minimum and maximum temperature.
These values can be examined or reset via the temperature controller (VMB1TC) or through the Velbus link software
via a PC connected to the Velbus PC interface (VMB1USB, VMB1RS of VMBRSUSB).
Differential thermostat
Using two sensors a differential thermostat can be created. When the difference in temperature between both sensors
reaches a certain value, the relay channel can be activated.
To achieve this, the first sensors must know the address of the second one. The second sensor must than be linked
to a relay channel. The temperature difference value is set on the first sensor.
Factory settings
After receiving this module, following factory default settings are already stored into the sensor:
Description Factor
y
default
Zone number No zone
Differential sensor address None
Operatin
g
mode Heatin
g
Un
j
am heatin
g
valve Disabled
Un
j
am heatin
g
valve circulation pump Disabled
Desired comfort temperature for heatin
g
22°C
Desired da
y
temperature for heatin
g
20°C
Desired ni
g
ht temperature for heatin
g
15°C
A
nti-freeze safe
g
uard 5°C
Heatin
g
limit 30°C
Temperature difference
(
fast heatin
g
/coolin
g
or differential thermostat
)
3°C
Calibration factor -2.5°C
H
y
steresis 0.5°C
Desired comfort temperature for coolin
g
21°C
Desired da
y
temperature for coolin
g
23°C
Desired ni
g
ht temperature for coolin
g
26°C
Lower limit coolin
g
preset ran
g
e 16°C
Upper limit coolin
g
preset ran
g
e 36°C
Low temperature alarm 3°C
Hi
g
h temperature alarm 30°C
Default duration temporar
y
mode
(
sleep timer
)
1 ho ur
Time interval for automatic transmission temperature Disabled
Local control Unlocked
C
y
clin
g
protection dela
y
1 minute