32 VMB1TS manual – edition 2
Remotely set cooling mode
With the lower left button on the second page of the control panel the temperature sensor is set in cooling mode.
1. Remember the address of the sensor module to
reinstate it later.
2. Set the address of the sensor module to ‘A1’.
The cooling mode LED flashes to indicate learning
mode for pushbuttons that place the module in
cooling mode.
Remark:
When multiple sensor modules needs to react to
the same pushbutton, remember their addresses
and set them also toA1’.
3. Select the second page of the control panel by
pressing the small pushbutton.
4. Press and hold the ‘Cooling’ pushbutton
(at least 1 second) until its indication LED starts
flashing.
Remark:
As long as the pushbutton is pressed, the LEDs on
the sensor module will be off. This to confirm that
the pushbutton is assigned.
5. Repeat step 4 in case other pushbuttons must set
the sensor module in cooling mode.
6. Reinstate the address of the sensor module(s) to
its (their) original value.
ADDR = A1