Capaciteitsmeting
Ran
g
e Resolution Accurac
y
4n
f
1
p
F ±
(
5.0% of rd
g
+ 5 di
g
its
)
40nF 10
p
F
± (3.0% of rdg + 5 digits)
400n
F
100
pF
4
µ
F 1nF
40
µ
F 10nF
200
µF
100n
F
Frequency measurements
Ran
g
e Resolution Accurac
y
9.999Hz 0.001Hz
± (0.1% of rdg + 1 digit)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
199.99kHz 100Hz
> 200kHz 100Hz Uns
p
ecified @ > 200kHz
Amplitude vs. frequency measurement. (Input voltage): 0.6Vrms to
max.250Vrms
For accurate measurements: amplitude between 1Vrms and 3Vrms
Use this device with original accessories only. Velleman nv cannot
be held responsible in the event of damage or injury resulted from
(incorrect) use of this device. For more info concerning this
product and the latest version of this user manual, please visit our
website www.velleman.eu. The information in this manual is
subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman
nv. All worldwide rights reserved. No part of this manual may be copied, reproduced,
translated or reduced to any electronic medium or otherwise without the prior written
consent of the copyright holder.
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 72 73

Comentarios a estos manuales

Sin comentarios